Skip to main content
Version: Pre-Released

Distance Between Grill and Worktop Back/End

Check Rule

VentilationGrillToEOWandBOWRule

Distance between grill and back/end of the worktop.

Notification level: ℹ

KeyValue
IDVentilationGrillToEOWandBOWRule
Translation key (back of worktop case)min_distance_grill_and_BOW_title
min_distance_grill_and_BOW_error_message
Translation key (end of worktop case)min_distance_grill_and_EOW_title
min_distance_grill_and_EOW_error_message

Behavior

This rule checks the distance between the ventilation grill and the back or the end of the worktop in order to avoid the user to plan a dangerous kitchen.

The distance is checked in the left, right or back direction.


Trigger Conditions

If the distance between the ventilation grill and the back or the end of the worktop is less than the chosen distance parameter, the rule is triggered and the application recommends to move the ventilation grill to another position.


Overload Parameter

Key nameTypeDefault valueDescription
minDistancenumber50This parameter defines the necessary minimum distance of the ventilation grill to the end of the worktop. Mandatory.
minDistanceBacknumber60This parameter defines the necessary minimum distance of the ventilation grill to the back of the worktop. Mandatory.
distancenumber50(Deprecated. Use minDistance instead)
This parameter defines the necessary minimum distance of the ventilation grill to the end of the worktop. Mandatory.
backdistancenumber60(Deprecated. Use minDistanceBack instead)
This parameter defines the necessary minimum distance of the ventilation grill to the back of the worktop. Mandatory.

Sample

{
"minDistance":50,
"minDistanceBack":60
}

Illustration

Case 1 – Back of the worktop

The ventilation grill is close to the back of the worktop, the rule is triggered and informs the user to change the position of the ventilation grill. An animation is displayed to guide the user through the changes.

Ventilation grill too close

Once the user has moved the ventilation grill away from the back of the worktop to a distance equal to or more than 60 mm (the overload value in this example), the design is error free.

Ventilation grill too close

Case 2 – End of the worktop

The ventilation grill is close to the end of the worktop, the rule is triggered and informs the user to change the position of the ventilation grill. An animation is displayed to guide the user through the changes.

Ventilation grill too close

Once the user has moved the ventilation grill away from the end of the worktop to a distance equal to or more than 50mm (the overload value in this example), the design is error free.

Ventilation grill too close