Skip to main content
Version: Pre-Released

Parameters for a Sink

This document contains all the possible or required parameters to set up sinks in the Kitchen application.

➡️ See the tutorial Set Up Sinks and Taps for a concrete case on the use of parameters in 3DCloud and Assembly Editor.

Mandatory Parameters

The following parameters are mandatory and must be set for a sink product.

NameTypeDefault ValuePossible ValuesVisibleFunction
widthreal[0 ;∞]anyDefines the product size of the model on the X-axis (from left to right).
depthreal[0 ;∞]anyDefines the product size of the model on the Y-axis (from front to back).
heightreal[0 ;∞]anyDefines the product size of the model on the Z-axis (from bottom to top).

Optional Parameters

Reserved names

The following parameters are optional and the name of the parameter are reserved words (cannot be modified).

Parameters for worktop export data

The following parameters are used to configure the worktop export data. It you do not use the linear export feature, none of these parameters are required.

NameTypeDefault ValuePossible ValuesVisibleFunction
addDrainerGroovesbooleanTRUE / FALSEanyDefines whether the sink has drainer grooves.
drainerGroovesproductanyDefines the drainer grooves product.
Requires addDrainerGrooves [boolean].
drainerGroovesPositionintegeranyDefines whether the drainer grooves is on the left or the right side, or both.
Requires addDrainerGrooves [boolean].
sinkBowlCenterXreal[-∞;∞]anyDefines the position of the bowls on the X-axis.
sinkBowlCenterYreal[-∞;∞]anyDefines the position of the bowls on the Y-axis.

Parameters for full-depth sinks

The following parameters are used to configure the full-depth feature for your sink. Full-depth sinks behave differently in the planner.

NameTypeDefault ValuePossible ValuesVisibleFunction
isFullDepthbooleanTRUE / FALSEanyMust be true if the sink is full depth.
fullDepthCutWidthreal[0;∞]anyDefines the cut width on which there is no worktop. If not defined, the width of the sink is used instead.
fullDepthThicknessCompatibilityreal[0;∞]anyDefines the list (or range) of the compatible worktop thickness on the left and right of the sink.
It is used in the FullDepthSinkThickness

The following parameters are optional and the name of the parameter are recommended (can be modified). To set up these parameters you can chose whatever the name you want.

NameTypeDefault ValuePossible ValuesVisibleFunction
numberOfBowlsinteger2[1;2]anyDefines the number of bowls for a sink. This parameter can be used in sink assemblies to impact number of lids.
sinkThickreal[-∞;∞]anyDefines the size of the visible part of the sink on the top of the worktop. This thickness parameter is used to define the position of the sink into a cabinet.
xTapOffsetreal[-∞;∞]anyDefines the position of the tap on the X-axis.
Depending on your data, it can be necessary even if the tap is outside the sink.
yTapOffsetreal[-∞;∞]anyDefines the position of the tap on the Y-axis.
Depending on your data, it can be necessary even if the tap is outside the sink.
zTapOffsetreal[-∞;∞]anyDefines the position of the tap on the Z-axis.