AB Dimensions for a Single Cut of Wall Panel
WallPanelMinDimensionABSingleCutRule
AB Dimensions of a single cut for a wall panel configuration.
Notification level: ⚠
Key | Value |
---|---|
ID | WallPanelMinDimensionABSingleCutRule |
Translation key | wallpanel_min_dimAB_single_cut_title wallpanel_min_dimAB_single_cut_error_message |
wallpanel_min_dimAB_single_cut_full_depth_title wallpanel_min_dimAB_single_cut_full_depth_error_message |
Behavior
This rule checks the dimensions of a single cut for a wall panel configuration in order to prevent the user from planning an invalid kitchen.
This rule excludes the verification for wall panel with the type "glass".
The dimensions A and B for a single cut are represented as follows:
Note: Full depth cut could be made by dragging one of the end points of the cut to the adjacent wallpanel corner as shown below.
Trigger Conditions
This rule is triggered if the dimensions of a single cut is less than the parameter set in the wall panel configuration. The minDistance
and minDistanceFullDepth
overloads can also be used to overload the values from the wall panel configuration. If minDistance
is provided, the A and B dimensions are compared to the biggest value between the wall panel configuration and minDistance
. If the minDistanceFullDepth
is provided and the cut is a full depth cut, the A and B dimensions are compared to the biggest value between the wall panel configuration and minDistanceFullDepth
. If the cut is a full depth cut, the condition for minDistance
is disregarded and the rule is triggered if the A & B Dimension of the single cut is less than minDistanceFullDepth
.
Overload Parameter
Key name | Type | Default value | Description |
---|---|---|---|
minDistance | number | 55 | This parameter defines the necessary minimum dimension for a single cut. Optional. |
minDistanceFullDepth | number | 10 | This parameter defines the necessary minimum dimension for a single cut, if the cut is a full depth cut . Optional. |
Sample
{
"minDistance":55,
"minDistanceFullDepth":10
}
Illustration
The dimensions of single cut is less than the chosen dimension parameter for a wall panel, the rule is triggered and warns the user to change the dimensions of this single cut. An animation is displayed to guide the user through the changes.
case 1
Once the user has changed the dimensions for a value greater than or equal to 55 mm (the overload value in this example) the design is error free.
case 2
Once the user has changed the dimensions for a value greater than or equal to 10 mm (the overload value in this example) the design is error free.
Note: The rule will be triggered for the maximum value considering overload value and product operation value.